44+ Low Air Loss Mattress Vs Alternating Pressure Mattress
The Hillrom 300 Wound Surface with alternating pressure and low air loss capabilities is an affordable option for a range of care settings.
Low air loss mattress vs alternating pressure mattress. The cover functions exactly the same as a low air loss mattress with the same perks. Alternating pressure low air loss in a highly specialized cover to address the five primary environmental factors that lead to the. Even then in case of any sort of discomfort you can always control the friction level in an alternating pressure mattress. The new international pressure ulcer treatment guidelines specify the following.
Designed to prevent treat and heal pressure ulcers in the home or long term care setting. For use in the prevention and treatment of decubitus ulcers. Quiet high volume pump. An alternating pressure mattress can provide your burnt skin the air and oxygen it requires to heal.
When selecting linens and incontinence pads to place on support surfaces with air-fluidized or low-air-loss. That said alternating pressure mattresses only address one issue. It brings along minimal friction. Low air loss on the other hand addresses pressure heat moisture build-up and friction.
When choosing the best alternating pressure mattress youll want to consider how long the patient will be bedridden as one of the primary factors in your evaluation. The Altus Series Alternating Pressure Pump and Low Air Loss Mattress System improves patient comfort while providing effective pressure ulcer prevention and treatment. While a lateral rotation mattress does help prevent and treat stages I-IV pressure ulcers an Alternating Pressure Mattress with Low Air Loss may be a more approriate and more economical choice to treat and prevent stages I-IV pressure ulcers. Alternating Pressure Mattress Alternates inflation and deflation of cells to constantly change pressure points and promote circulation.
Both low air loss and alternating pressure mattresses will need to have a consistent air flow to ensure they work effectively. The floating sensation is still present and the airflow will still keep the patients skin dry. Low Air Loss Mattress Floats the patient on air-filled cells while circulating air across the skin to reduce moisture and help maintain a constant skin interface pressure True Air Loss utilizes 100-150 liters of air per minute to maintain normal skin temperature and moisture levels yet will not dry out therapeutic dressings. In addition a doctor can advise if youll need to consider adding low air loss as part of your criteria for finding the appropriate model for you or a loved one.
From the hospital to the home this easy to use surface has features and safety components to support the needs of patients and caregivers. In our analysis of product reviews its evident that the majority of caregivers prefer low air loss mattresses. Active mattress replacement system provides both alternating pressure and low air loss to optimize pressure redistribution shearfriction reduction and microclimate control. Continuity of care for safer skin.
Alternating Pressure Mattress Systems with Low Air Loss are the preferred therapy for the prevention and treatment of Stages I - IV pressure ulcers. This is because all mattresses will and do lose air over time and if this happens the structure of the mattress changes leading to issues like sore backs. The combined mattress system is designed with a low air loss cover on which the patient can rest and an alternating pressure base. The mattress is designed with a low air loss cover.
Pressure relief air mattresses include Alternating Pressure mattress systems Low Air Loss mattresses and Lateral Rotation mattress systems each explained in more detail below used for pressure prevention when patients are at risk of developing pressure ulcers or pressure sores also commonly referred to as bed soresThese mattresses are used in both home care and hospital.